The srs830 module

DSP Lock-In Amplifier

Classes

SRS830

class src.instruments.srs830.SRS830(experiment, name='SRS830: Lock-in amplifier', spec=None)[source]

Driver for an SRS830 lock-in amplifier.

Methods

finalize()[source]

Close the communication channel.

getActions()[source]

Get the list of supported actions.

getAddress()[source]

Return the instrument’s VISA resource address.

getAllParameters()[source]

Read all lock-in parameters.

getDetectionHarmonic()[source]

Get the lock-in’s detection harmonic.

getInputConfiguration()[source]

Get the lock-in’s input configuration.

getInputCoupling()[source]

Get the lock-in’s input coupling configuration.

getInputGrounding()[source]

Get the lock-in’s input shield grounding configuration.

getInputNotch()[source]

Get the input line notch filter status.

getLowPassFilter()[source]

Get the lock-in’s low-pass filter slope.

getReferenceFrequency()[source]

Get the lock-in’s reference frequency.

getReferencePhase()[source]

Get the lock-in’s reference phase.

getReferenceSource()[source]

Get the lock-in’s reference source.

getReferenceTrigger()[source]

Get the lock-in’s reference trigger for external reference mode.

getReferenceVoltage()[source]

Get the lock-in’s reference voltage.

getReserveMode()[source]

Get the lock-in’s reserve mode.

getSensitivity()[source]

Get the lock-in’s sensitivity.

getSynchronousFilter()[source]

Get the lock-in’s synchronous filter status.

getTimeConstant()[source]

Get the lock-in’s time constant.

initialize()[source]

Open the communication channel.

readAverageVoltageXY(pretime, numavg, intertime)[source]

Take an average in- and out-of-phase voltage measurement.

readSingleVoltageXY()[source]

Take a single in- and out-of-phase voltage measurement.

setDetectionHarmonic(harm)[source]

Set the lock-in’s detection harmonic.

setInputConfiguration(config)[source]

Set the lock-in’s input configuration.

setInputCoupling(cpl)[source]

Set the lock-in’s input coupling configuration.

setInputGrounding(ground)[source]

Set the lock-in’s input shield grounding configuration.

setInputNotch(notch)[source]

Set the input line notch filter status.

setLowPassFilter(filt)[source]

Set the lock-in’s low-pass filter slope.

setReferenceFrequency(freq)[source]

Set the lock-in’s reference frequency.

setReferencePhase(phase)[source]

Set the lock-in’s reference phase.

setReferenceSource(source)[source]

Set the lock-in’s reference source.

setReferenceTrigger(trig)[source]

Set the lock-in’s reference trigger for external reference mode.

setReferenceVoltage(vref)[source]

Set the lock-in’s reference voltage.

setReserveMode(mode)[source]

Set the lock-in’s reserve mode.

setSensitivity(sens)[source]

Set the lock-in’s sensitivity.

setSynchronousFilter(filt)[source]

Set the lock-in’s synchronous filter status.

setTimeConstant(tconst)[source]

Set the lock-in’s time constant.

Table Of Contents

Previous topic

The ps120 module

Next topic

The heliox module

This Page